The hot channel is a solution for the heat dissipation of the server cabinet in the computer room. The hot channel is closed by the top skylight module, the normally closed double door, the frame installation unit, the auxiliary installation parts, etc., so that the cold air does not leak to other areas, the mixing with the air after heat exchange is avoided, the refrigeration utilization rate is improved, the energy consumption of the computer room is effectively reduced, and the service life of the equipment is prolonged.
Send Message Get Price
| Hot Aisle Closure Assembly - Aisle Door | |||
| S/N | Model | NAME | PRODUCT FEATURES |
| 1 | HJL-MEN-01 | Access door | Applicable to 1000mm wide channel, manual sliding door, steel door frame, embedded tempered glass, with door lock |
| 2 | HJL-MEN-02 | Applicable to 1000mm wide channel, automatic sliding door, steel door frame, embedded tempered glass, access lock with password, touch screen | |
| 3 | HJL-MEN-03 | Applicable to 1000mm wide channel, automatic sliding door, aluminum alloy door frame, embedded tempered glass, access lock with password, touch screen | |
| 4 | HJL-MEN-04 | Applicable to 1200mm wide channel, automatic sliding door, steel door frame, embedded tempered glass, with door lock | |
| 5 | HJL-MEN-05 | Applicable to 1200mm wide channel, automatic sliding door, steel door frame, embedded tempered glass, access lock with password, touch screen | |
| 6 | HJL-MEN-06 | Applicable to 1200mm wide channel, automatic sliding door, aluminum alloy door frame, embedded tempered glass, access lock with password, touch screen | |
| 7 | HJL-MEN-07 | Applicable to 1000mm wide channel, sliding door, steel door frame, embedded tempered glass, hidden door closers, with door lock | |
| 8 | HJL-MEN-08 | Applicable to 1000mm wide channel, sliding door, steel door frame, embedded tempered glass, hidden door closers, access lock with electronic password, electric touch screen | |
| 9 | HJL-MEN-09 | Applicable to 1200mm wide channel, sliding door, steel door frame, embedded tempered glass, hidden door closers, with door lock | |
| 10 | HJL-MEN-010 | Applicable to 1200mm wide channel, sliding door, steel door frame, embedded tempered glass, hidden door closers, access lock with electronic password, electric touch screen | |
| Hot Aisle Closure Assembly - Fixed Skylight | |||
| S/N | Model | NAME | PRODUCT FEATURES |
| 1 | HJL-PTC-01 | Fixed skylight | Suitable for 300 wide cabinet, 1000mm wide channel, steel frame + glass |
| 2 | HJL-PTC-02 | Suitable for 300 wide cabinet, 1200mm wide channel, steel frame + glass | |
| 3 | HJL-PTC-03 | For 600 wide cabinet, 1000mm wide channel, steel frame + glass | |
| 4 | HJL-PTC-04 | For 600 wide cabinet, 1200mm wide channel, steel frame + glass | |
| 5 | HJL-PTC-05 | For 800 wide cabinet, 1000mm wide channel, steel frame + glass | |
| 6 | HJL-PTC-06 | For 800 wide cabinet, 1200mm wide channel, steel frame + glass | |
| Hot Aisle Closure Assembly - Side Seal Plate | |||
| S/N | Model | NAME | PRODUCT FEATURES |
| 1 | HJL-CFB-01 | Side Seal Plate | Suitable for 300 wide cabinet, steel plate production |
| 2 | HJL-CFB-02 | Suitable for 600 wide cabinet, steel plate production | |
| 3 | HJL-CFB-03 | Suitable for 800 wide cabinet, steel plate production | |
| Hot Aisle Closure Assembly - Control System | |||
| S/N | Model | NAME | PRODUCT FEATURES |
| 1 | HJL-KZX-01 | the lighting system | Including sunroof lighting and infrared remote sensing switch |
| 2 | HJL-KZX-02 | ЧИСЛЕННОСТЬ ОБУЧАЮЩИХСЯ И УЧИТЕЛЕЙ В ГОСУДАРСТВЕННЫХ И МУНИЦИПАЛЬНЫХ ОБЩЕОБРАЗОВАТЕЛЬНЫХ ОРГАНИЗАЦИЯХ | Includes monitoring unit and sensor |
Note: Specifications are subject to change without prior notice for product improvement. Data Sheet
Suitable for large computer room scenarios, single cabinet power support 1kW ~ 8kW, support total power 24kW ~ 100kW, total number of cabinets 6 ~ 15 units
Unit modular design, install the top of the back of the cabinet, each unit can be installed independently, and can be connected with adjacent units to facilitate disassembly and replacement
The centralized cooling method of the machine room, the cold air fills the entire machine room, is sucked into the inside of the equipment through the fan of the IT equipment, and the hot air formed by the absorption of heat is discharged from the rear of the cabinet into the hot channel
An air duct is set at the top of the hot channel to inhale hot air into the air conditioner to refrigerate and enter the next cycle
The frame and the horizontal bracket of the cabinet are connected by special connecting holes to increase the overall stability effect; in addition to the reinforcement channel itself, it also needs to play a convenient expansion function; the mounting holes on the mounting bracket are arranged in a ≥ 25mm grid mode for universal assembly
The closed window of the passage is glass material, which is coordinated and beautiful with the computer room as a whole. The glass used complies with the GB 15763.2 -2005 "Safety Glass for Buildings" standard to prevent the impact of glass shattering on the data room and maintenance personnel
The movable door is designed to be normally closed, and a buffer automatic closing device is installed, and the sliding handle is set on both sides to open flexibly
The door is sealed with a strip between the door and the rack, and the sealing degree is tight, which can effectively curb the outflow of cold air