The J-net Rack HR1000 is a next-generation smart micro-module data center solution that integrates power distribution, UPS, monitoring, cooling, fire protection, lighting and cabinet systems. Provide an unprecedented excellent working environment and reliable guarantee platform for small and micro IT room Application Scenarios.
Send Message Get Price
| Single cabinet configuration table | |
| Cabinet system | |
| Dimensions (H x W x D MM) | 2000(2200)X 600X 1350 |
| Capacity | 42U(46U) |
| Protection Rating | IP30 |
| Operating Temperature | -20℃~45℃ |
| Installation | Concrete floor, raised floor |
| Maximum load per cabinet | 6KW |
| IT cabinet bearing requirements | Static load 1500kg, dynamic load 1000kg |
| Cooling Generating Systems | |
| Rated AC input power supply | 220V AC 50Hz |
| Cooling capacity (L35/L35) | 3.5KW |
| Rated Input Power | 1270W |
| Rated current | 8A |
| Heating Capacity | 1000W |
| Refrigerant | R410A |
| Sensitivity to heat ratio | ≥0.99 |
| Energy Efficiency Ratio | ≥3.2 |
| Air distribution | Front air supply, rear air return |
| Installation | Rack mounting |
| - Distribution System | |
| Lightning protection level | Class C, In 20ka, Imax40ka |
| Power Input | Single and dual channels optional |
| Dual Power Switching System | Optional for 2-way input |
| UPS Capacity | 6KVA / 10KVA |
| UPS Architecture | N,N+1,2N |
| Input Voltage | 220V Single Phase 380V Three Phase |
| Output voltage | 220V~240V AC 50Hz 380V~400V AC 50Hz |
| Output power factor | 0.9 |
| Battery Configuration | Rack-mounted lithium batteries, lithium battery cabinets |
| Backup time | 15~30min |
| Repair bypass | Standard |
| ЧИСЛЕННОСТЬ ОБУЧАЮЩИХСЯ И УЧИТЕЛЕЙ В ГОСУДАРСТВЕННЫХ И МУНИЦИПАЛЬНЫХ ОБЩЕОБРАЗОВАТЕЛЬНЫХ ОРГАНИЗАЦИЯХ | |
| ЧИСЛЕННОСТЬ ОБУЧАЮЩИХСЯ И УЧИТЕЛЕЙ В ГОСУДАРСТВЕННЫХ И МУНИЦИПАЛЬНЫХ ОБЩЕОБРАЗОВАТЕЛЬНЫХ ОРГАНИЗАЦИЯХ | Support remote web interface access |
| Local Interface | Standard 10-inch touch screen |
| Mobile O&M | Mobile App, SMS Alerts |
| Smoke detector | Optional |
| Water immersion | Optional |
| Temperature and humidity | Optional |
| door-lock | Optional |
| Video monitoring | Optional |
| Multi-cabinet configuration table | |||
| Cabinet system | Cooling Generating Systems | ||
| Dimensions (H x W x D MM) | 2000(2200)X 600X 1350 | Rated AC input power supply | 220V AC 50Hz |
| Piping Type | Multiple cabinets | Cooling capacity (L35/L35) | 3.5KW*2 |
| Number of single cabinets | 2-3 units | Rated Input Power | 1270W*2 |
| Capacity | 42U (46U) * number of cabinets | Rated current | 8A |
| Protection Rating | IP30 | Heating Capacity | 1000W*2 |
| Operating Temperature | -20℃~45℃ | Refrigerant | R410A |
| Installation | Concrete floor, raised floor | Sensitivity to heat ratio | ≥0.99 |
| Maximum load per cabinet | 6KW | Energy Efficiency Ratio | ≥3.2 |
| Supports maximum power consumption of IT load | 10KW | Air distribution | Front air supply, rear air return |
| IT cabinet bearing requirements | Static load 1500kg, dynamic load 1000kg | Installation | Rack mounting |
| - Distribution System | ЧИСЛЕННОСТЬ ОБУЧАЮЩИХСЯ И УЧИТЕЛЕЙ В ГОСУДАРСТВЕННЫХ И МУНИЦИПАЛЬНЫХ ОБЩЕОБРАЗОВАТЕЛЬНЫХ ОРГАНИЗАЦИЯХ | ||
| Lightning protection level | Class C, In 20ka, Imax40ka | ЧИСЛЕННОСТЬ ОБУЧАЮЩИХСЯ И УЧИТЕЛЕЙ В ГОСУДАРСТВЕННЫХ И МУНИЦИПАЛЬНЫХ ОБЩЕОБРАЗОВАТЕЛЬНЫХ ОРГАНИЗАЦИЯХ | Support remote web interface access |
| Power Input | Single and dual channels optional | Local Interface | Standard 10-inch touch screen |
| Dual Power Switching System | Optional for 2-way input | Mobile O&M | Mobile App, SMS Alerts |
| UPS Capacity | 10KVA | Smoke detector | Optional |
| UPS Architecture | N,N+1,2N | Water immersion | Optional |
| Input Voltage | 220V Single Phase 380V Three Phase | Temperature and humidity | Optional |
| Output voltage | 220V~240V AC 50Hz 380V~400V AC 50Hz |
door-lock | Optional |
| Output power factor | 0.9 | Video monitoring | Optional |
| Backup time | 15~30min | Fire Fighting System | |
| Repair bypass | Standard | Rack fire extinguishers | Temperature detection and fire extinguishing all-in-one machine |
Note: Specifications are subject to change without prior notice for product improvement. Data Sheet
In-depth integration of data center infrastructure products in one cabinet, on-site installation is simply fixed, powered on, and construction time is only 4 hours
A single system is configured with a color touch screen, which can display all system parameters, monitoring information, alarm records, etc. locally
Network monitoring management, which can be connected to a third-party monitoring system to achieve unattended management of remote browsing monitoring
Rack-mounted air-conditioning system, saving air-conditioning cabinet installation space
Frequency conversion refrigeration technology, cold and hot channel isolation, PUE as low as 1.5
The welded frame can meet the requirements of a magnitude 9 earthquake
Compatible with dehumidification heating function to avoid the risk of condensation
Real-time monitoring of internal resistance, voltage and temperature of the battery, intelligent disconnection of overheating to prevent fire
Optional cabinet-level fire extinguishers to meet fire protection needs
It is suitable for various power consumption scenar ios such as residential buildings and commercial office buildings