High power micro inverter, output power up to 2000VA.
Component-level MPPT and data monitoring, higher power generation and simpler operation and maintenance.
With reactive power compensation function, in line with NB/T 32004-2018 standard.
Meets the most stringent North American fast shutdown requirements, safer to be applied to rooftop power stations.
Model Number | HJ-MG0003-W (500W) |
Input (DC) | |
Suitable Array Power (W) | 360~600+ |
Max Input Voltage (V) | 65 |
MPPT Voltage Range (V) | 16*60 |
Start-up Voltage (V) | 22 |
Max Input Current (A) | 15 |
Max Input Short-Circuit Current (A) | 25 |
Number of MPPTs | 1 |
Max Input Route per MPPT | 1 |
Output (AC) | |
Rated Output Power (VA) | 450 |
Rated Output Current (A) | 2.05 |
Output Voltage Range (V) | 220/180*275 |
Rated Frequency Range (Hz) | 50/45*55 |
Adjustable Power Factor (Rated Power) | >0.99 Default 0.8 ahead…0.8 behind |
Total Harmonic Distortion (Rated Power) | <3% |
Max Number of Strings per Phase (2.5mm² Total) | 11 |
Max Number of Strings per Phase (4mm² Total) | 15 |
Max Number of Strings per Phase (6mm² Total) | 19 |
Efficiency | |
Peak Efficiency | 96.6% |
MPPT Efficiency | 99.8% |
Night Loss (mW) | <50 |
Mechanical Parameters | |
Operating Temperature (℃) | -40*+65 |
Dimensions (W×H×D mm) | 182×164×30 |
Weight (kg) | 1.75 |
Protection Level | Outdoor-IP67 |
Cooling Method | Natural convection |
Safety and Protection Features | |
Anti-island Protection, Input Anti-reverse Protection, Output Short-Circuit Protection, Output Overcurrent Protection, Output Overvoltage Protection, 6000V Surge Protection | |
Features | |
Active Power Regulation, Reactive Power Regulation, High Voltage Ride Through (optional), Low Voltage Ride Through (optional), High Frequency Transformer Isolation | |
Others | |
Communication Method | Sub-1G |
Model Number | HJ-MG0003-W (1000W) |
Input (DC) | |
Suitable Array Power (W) | 400*670+ |
Max Input Voltage (V) | 65 |
MPPT Voltage Range (V) | 16*60 |
Start-up Voltage (V) | 22 |
Max Input Current (A) | 2×15 |
Max Input Short-Circuit Current (A) | 2×25 |
Number of MPPTs | 2 |
Max Input Route per MPPT | 1 |
Output (AC) | |
Rated Output Power (VA) | 900 |
Rated Output Current (A) | 4.09 |
Output Voltage Range (V) | 220/180*275 |
Rated Frequency Range (Hz) | 50/45*55 |
Adjustable Power Factor (Rated Power) | >0.99 Default 0.8 ahead…0.8 behind |
Total Harmonic Distortion (Rated Power) | <3% |
Max Number of Strings per Phase (2.5mm² Total) | 5 |
Max Number of Strings per Phase (4mm² Total) | 7 |
Max Number of Strings per Phase (6mm² Total) | 9 |
Efficiency | |
Peak Efficiency | 96.50% |
MPPT Efficiency | 99.80% |
Night Loss (mW) | <50 |
Mechanical Parameters | |
Operating Temperature (℃) | -40*+65 |
Dimensions (W×H×D mm) | 261×180×35.1 |
Weight (kg) | 3.2 |
Protection Level | Outdoor-IP67 |
Cooling Method | Natural convection |
Safety and Protection Features | |
Anti-island Protection, Input Anti-reverse Protection, Output Short-Circuit Protection, Output Overcurrent Protection, Output Overvoltage Protection, 6000V Surge Protection | |
Features | |
Active Power Regulation, Reactive Power Regulation, High Voltage Ride Through (optional), Low Voltage Ride Through (optional), High Frequency Transformer Isolation | |
Others | |
Communication Method | Sub-1G |
Isolation Method | High Frequency Transformer Isolation |
Grid Connection Standard | NB/T 32004-2018 |
Model Number | HJ-MG0003-W (2000W) |
Input (DC) | |
Suitable Array Power (W) | 400~670+ |
Max Input Voltage (V) | 65 |
MPPT Voltage Range (V) | 16~60 |
Start-up Voltage (V) | 22 |
Max Input Current (A) | 4×16 |
Max Input Short-Circuit Current (A) | 4×25 |
Number of MPPTs | 4 |
Max Input Route per MPPT | 1 |
Output (AC) | |
Rated Output Power (VA) | 2000 |
Rated Output Current (A) | 9.09 |
Output Voltage Range (V) | 220/180*275 |
Rated Frequency Range (Hz) | 50/45*55 |
Adjustable Power Factor (Rated Power) | >0.99 Default |
Total Harmonic Distortion (Rated Power) | <3% |
Max Number of Strings per Phase (2.5mm² Total) | 2 |
Max Number of Strings per Phase (4mm² Total) | 3 |
Max Number of Strings per Phase (6mm² Total) | 4 |
Efficiency | |
Peak Efficiency | 96.50% |
MPPT Efficiency | 99.80% |
Night Loss (mW) | <50 |
Mechanical Parameters | |
Operating Temperature (℃) | -40*+65 |
Dimensions (W×H×D mm) | 331×218×40.6 |
Weight (kg) | 5.56 |
Protection Level | Outdoor-IP67 |
Cooling Method | Natural convection |
Safety and Protection Features | |
Anti-island Protection, Input Anti-reverse Protection, Output Short-Circuit Protection, Output Overcurrent Protection, Output Overvoltage Protection, 6000V Surge Protection | |
Features | |
Active Power Regulation, Reactive Power Regulation, High Voltage Ride Through (optional), Low Voltage Ride Through (optional), High Frequency Transformer Isolation | |
Others | |
Communication Method | Sub-1G |
Isolation Method | High Frequency Transformer Isolation |
Grid Connection Standard | NB/T 32004-2018 |
Note: Specifications are subject to change without prior notice for product improvement. Data Sheet
We're committed to providing prompt, professional support to ensure your energy needs are always met with the highest level of service.
We're here to answer your questions and provide the energy solutions that best fit your needs.