The Site Hybrid Energy product line is centered on green low-carbon, high-efficiency, and intelligent coordination principles. It covers integrated power supplies, AC-DC power supplies, outdoor 5G power boxes, indoor/outdoor hybrid energy cabinets, and equipment-room power cabinets for all-scenario power supply. It fully supports renewable energy sources such as PV and wind, establishing a hybrid power system of “Renewable Energy + Grid Power + Energy Storage.”
Send Message Get Price
| Base Station Energy System Specifications | |||
| Product Model | HJ-CHI-18030-W | HJ-CHI-36040-W | |
| Cabinet Parameters | Dimensions | 1600mm*600mm*600mm | 2200mm*700mm*700mm |
| Application Scenario | Indoor Floor-Standing | Indoor Floor-Standing | |
| Weight | ≤95 kg (excluding battery) | ≤145 kg (excluding battery) | |
| Input Characteristics | AC Input | AC 380V/220V, 50Hz; MCB 63A/4P; SPD ×1; Output 16A ×1 (optional) | AC 380V/220V, 50Hz; MCB 63A/4P; SPD ×1; Output 16A ×1 (optional) |
| PV/Wind Input | Supported, optional | Supported, optional | |
| Max. Power Supply | Capacity | 18KW(300A) | 36KW(600A) |
| Efficiency | 93% (96% optional) | 93% (96% optional) | |
| Rectifier | Single Module Spec | 48V/50A module, 75A optional | 48V/50A module, 75A optional |
| Total Capacity | Max. 18 kW (300A) | Max. 36 kW (600A) | |
| Note: Combined rectifier + PV capacity is 300A; when rectifiers are fully populated, no PV capacity is available | Note: Combined rectifier + PV capacity is 300A; when rectifiers are fully populated, no PV capacity is available | ||
| PV Controller (MPPT) | Single Module Spec | 48V/50A module, 75A optional | 48V, 50A or 75A optional |
| MPPT Input Voltage | 60~150V, optional (200V~400V) | 60~150V, optional (200V~400V) | |
| Total Capacity | Max. 18 kW (300A) | Max. 36 kW (600A) | |
| PV Modules | Max. PV Power (W) | Recommended 9 kW (3~18 kW optional) | Recommended 18 kW (3~36 kW optional) |
| Battery Parameters | Battery Rated Voltage (V) | 48V(40~60V) | 48V(40~60V) |
| Max. Charge/Discharge Current (A) | 90A (C-rate 0.3C) | 180A (C-rate 0.3C) | |
| Capacity | 30KWh | 40KWh | |
| Output Characteristics | Bypass AC Output | 220/230Vac(380/400Vac) | 220/230Vac(380/400Vac) |
| DC 48V Output Voltage | 43.2V DC ~ 58V DC (default 53.5V DC) | 43.2V DC ~ 58V DC (default 53.5V DC) | |
| Rated Output Power | Max. 18 kW (300A) | Max. 36 kW (600A) | |
| Peak Efficiency | 96% | 96% | |
| DC Output Interface | MCB: 125A×2, 63A×2, 32A×2, 16A×2 (configurable per customer) | MCB: 125A×2, 63A×2, 32A×2, 16A×2 (configurable per customer) | |
| Application Scenario | / | Grid-tied / Off-grid (optional) | Grid-tied / Off-grid (optional) |
Note: Specifications are subject to change without prior notice for product improvement.
Communication base stations (5G/4G), remote base stations
Island stations, border outposts, field exploration sites
Mining areas, construction sites, temporary camps
Island microgrids, off-grid villages and towns Backup/primary power in areas with unstable grid;
We're committed to providing prompt, professional support to ensure your energy needs are always met with the highest level of service.
We're here to answer your questions and provide the energy solutions that best fit your needs.