The single-phase stacked all-in-one system is a high-performance product. It comes in various models, making it adaptable to different application scenarios and regional needs.
Send Message Get Price
| Product Model | HJ-H05-H05 (k-7) | HJ-H10-H05 (k-8) | HJ-H15-H05 (k-9) |
| Battery Parameters | |||
| Battery Type | Li-ion / Lead-acid | ||
| Rated Battery Voltage [V] | 96 | ||
| Battery Voltage Range [V] | 80-450 | 80-467.2 | |
| Maximum Charging Current [A] | 60 | 60 | 60 |
| Maximum Discharge Current [A] | 60 | 60 | 60 |
| Photovoltaic Input | |||
| Maximum Photovoltaic Input Power [kW] | 10 | ||
| Maximum Photovoltaic Input Voltage [V] | 580 | ||
| MPPT Tracking Range [V] | 100-550 | ||
| Start-up Voltage [V] | 100 | ||
| Maximum Input Current [A] | 15/15 | ||
| Maximum Short-circuit Current [A] | 18.75/18.75 | 22.5/22.5 | |
| MPPT Trackers | 2 | ||
| MPPT Tracker Configuration | 1/1/1 | ||
| Grid Parameters | |||
| Rated Output Power [kVA] | 5/4.6 (DE) | 5/4.6 (DE) | 6 |
| Maximum Output Current [A] | 22.7 | 22.7 | 27.2/26 |
| Maximum Apparent Output Power [kVA] | 5/4.6 (DE) | 5/4.6 (DE) | 6 |
| Maximum Input Power [kVA] | 10 | 10 | 11.5 |
| Rated Grid Voltage [Vac] | 230 | 230 | 220/230 |
| Grid Voltage Range [Vac] | 180-270 | ||
| Rated Grid Frequency [Hz] | 50/60 | ||
| Power Factor | -0.8 ~ +0.8 | ||
| THDi | <3% | ||
| Backup Ports | |||
| Peak Backup Power [kVA] | 10 | 11.5 | |
| Rated Backup Power [kVA] | 5 | 6 | |
| Rated Backup Voltage [Vac] | 230 | 220/230 | |
| Rated Backup Frequency [Hz] | 50/60 | 50/60 | |
| Total Harmonic Distortion (Voltage) | <3% (Linear Load) / <5% (Non-linear Load) | ||
| DC Voltage | <100mV | ||
| Peak Ratio | 3:1 | ||
| Switching Time | <10ms | ||
| Efficiency | |||
| Maximum Efficiency | 97.30% | ||
| European Efficiency | 96.20% | ||
| Maximum Power Point Tracking Efficiency | 99.90% | ||
| Maximum Round-trip Efficiency | 90% | ||
| HMI & COMM. | |||
| Communication with BMS | CAN/RS-485 | ||
| Load Monitoring | Meter/CT/Backup box | ||
| External Communication | RS-485/WIFI/4G/Ethernet | ||
| User Interface | LED/LCD | ||
| Battery Parameters | |||
| Total Energy [kWh] | 5.3 | 10.6 | 15.9 |
| Battery Module | 102.4V 5.3kWh | ||
| Number of Modules | 1 | 2 | 3 |
| Battery Type | LFP (LiFePO4) | ||
| Rated Voltage [V] | 102.4 | 204.8 | 307.2 |
| Operating Voltage [V] | 80-116.8 | 160-233.6 | 240-350.4 |
| Maximum Charge/Discharge Current [A] | 52 | ||
| Sustained Discharge Power [kW] | 5 | 10 | 15 |
| General Parameters | |||
| Dimensions (W×D×H) [mm] | 740*220*970 | 740*220*1305 | 740*220*1640 |
| Approximate Weight [kg] | 86 | 136 | 186 |
| Enclosure Protection Rating | IP65 | ||
| Operating Temperature | Charging Temperature: 0℃~50℃ / Discharging Temperature: 0℃~50℃ | ||
| Storage Temperature | 0℃~35℃ | ||
| Humidity | ≤95% | ||
| Altitude [m] | ≤3000 | ||
| Cycle Life | Inverter: 5 years / 10 years; Battery: 10+ years, 6000 cycles (90% DoD, 25℃) | ||
| Installation | Stacked, Floor-mounted Installation | ||
| Certification | |||
| Grid Safety Standards | VDE-AR-N4105:2018, G98, G99, C10/11:2021, NTS 631, RD647:2020, UNE 217002:2020, CEI0-21, VDE 0126-1-1, NRS 097-2-1, AS/NZS 4777.2:2020, EN 50549-1 | CEI0-21, NRS 097, IEC 61727, IEC 62116, EREC G99 | |
| Safety Standards | IEC/EN 62109-1&2, IEC/EN 62477-1:2012 | ||
| Electromagnetic Compatibility | IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4 | ||
| Battery | UN38.3, IEC62619 | ||
Note: Specifications are subject to change without prior notice for product improvement. Data Sheet
UPS-grade redundancy protection to prevent backup load failure
Built-in EMS smart management system to automatically optimize home energy supply
Built-in power services, FCAS, VPP, etc.
The choice for most households, converting clean energy collected daily into household electricity expenditure.
We're committed to providing prompt, professional support to ensure your energy needs are always met with the highest level of service.
We're here to answer your questions and provide the energy solutions that best fit your needs.