The equipment in the machine room is specially used for installing, fixing and organizing cables. It is usually used for rationally arranging optical cables, cables, data cables and other cables in and out of the communication machine room, so that the wiring of the entire machine room is neat and orderly.
Send Message Get Price
| S/N | Model | NAME | Type | Width (mm) | Application scenarios | surface treatment |
| 1 | HJ ZXJ11-B1A3 | Flat Steel Walking Frame | monolayer | 300 | Outdoor | Hot-Dip Galvanized |
| 2 | HJ ZXJ11-B1A4 | Flat Steel Walking Frame | monolayer | 400 | Outdoor | Hot-Dip Galvanized |
| 3 | HJ ZXJ11-B1A6 | Flat Steel Walking Frame | monolayer | 600 | Outdoor | Hot-Dip Galvanized |
| 4 | HJ ZXJ11-B1A8 | Flat Steel Walking Frame | monolayer | 800 | Outdoor | Hot-Dip Galvanized |
| 5 | HJ ZXJ21-B1B3 | Flat Steel Walking Frame | monolayer | 300 | (indoor) | Electrolytic zinc-coated |
| 6 | HJ ZXJ21-B1B4 | Flat Steel Walking Frame | monolayer | 400 | (indoor) | Electrolytic zinc-coated |
| 7 | HJ ZXJ21-B1B6 | Flat Steel Walking Frame | monolayer | 600 | (indoor) | Electrolytic zinc-coated |
| 8 | HJ ZXJ21-B1B8 | Flat Steel Walking Frame | monolayer | 800 | (indoor) | Electrolytic zinc-coated |
| 9 | HJ ZXJ21-B1C3 | Flat Steel Walking Frame | monolayer | 300 | (indoor) | Electrostatic spraying |
| 10 | HJ ZXJ21-B1C4 | Flat Steel Walking Frame | monolayer | 400 | (indoor) | Electrostatic spraying |
| 11 | HJ ZXJ21-B1C6 | Flat Steel Walking Frame | monolayer | 600 | (indoor) | Electrostatic spraying |
| 12 | HJ ZXJ21-B1C8 | Flat Steel Walking Frame | monolayer | 800 | (indoor) | Electrostatic spraying |
| 13 | HJ ZXJ12-B1D3 | Flat Steel Walking Frame | double layered | 300 | Outdoor | Hot-Dip Galvanized |
| 14 | HJ ZXJ12-B1D4 | Flat Steel Walking Frame | double layered | 400 | Outdoor | Hot-Dip Galvanized |
| 15 | HJ ZXJ12-B1D6 | Flat Steel Walking Frame | double layered | 600 | Outdoor | Hot-Dip Galvanized |
| 16 | HJ ZXJ12-B1D8 | Flat Steel Walking Frame | double layered | 800 | Outdoor | Hot-Dip Galvanized |
| 17 | HJ ZXJ22-B1E3 | Flat Steel Walking Frame | double layered | 300 | (indoor) | Electrolytic zinc-coated |
| 18 | HJ ZXJ22-B1E4 | Flat Steel Walking Frame | double layered | 400 | (indoor) | Electrolytic zinc-coated |
| 19 | HJ ZXJ22-B1E6 | Flat Steel Walking Frame | double layered | 600 | (indoor) | Electrolytic zinc-coated |
| 20 | HJ ZXJ22-B1E8 | Flat Steel Walking Frame | double layered | 800 | (indoor) | Electrolytic zinc-coated |
| 21 | HJ ZXJ22-B1F3 | Flat Steel Walking Frame | double layered | 300 | (indoor) | Electrostatic spraying |
| 22 | HJ ZXJ22-B1F4 | Flat Steel Walking Frame | double layered | 400 | (indoor) | Electrostatic spraying |
| 23 | HJ ZXJ22-B1F6 | Flat Steel Walking Frame | double layered | 600 | (indoor) | Electrostatic spraying |
| 24 | HJ ZXJ22-B1F8 | Flat Steel Walking Frame | double layered | 800 | (indoor) | Electrostatic spraying |
HJ ZXJ1 (2) 1-B1 series single-layer flat steel walking frame per meter configuration table:
| S/N | Name | unit | quantity | REMARK |
| 1 | keel | m | 2 | When the length is 1 meter and the width of the leadframe is ≥ 800 mm, the middle position of the leadframe is increased by 1 main keel |
| 2 | Horizontal Gear | Cables | 4 | The length is the width of the leadframe, and the interval is 250mm. |
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room |
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height |
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack |
HJ ZXJ1 (2) 2-B1 series double-layer flat steel walking frame per meter configuration table:
| S/N | Name | unit | quantity | REMARK |
| 1 | keel | m | 4 | When the length is 1 meter and the width of the leadframe is ≥ 800 mm, the middle position of the leadframe is increased by 1 main keel |
| 2 | Horizontal Gear | Cables | 8 | The length is the width of the leadframe, and the interval is 250mm. |
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room |
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height |
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack |
| 6 | Double Spaced Columns | Cables | 1.33 | Length is double interval, double interval column height ≥ 250mm |
Note: Specifications are subject to change without prior notice for product improvement. Data Sheet
Open design, solid structure, wide variety, easy installation, beautiful appearance
It is suitable for various power consumption scenar ios such as residential buildings and commercial office buildings
We're committed to providing prompt, professional support to ensure your energy needs are always met with the highest level of service.
We're here to answer your questions and provide the energy solutions that best fit your needs.